UNITS OF COMPETENCE
We offer certification examinations in the following IECEx CoPC units of competence:
For information about the application & assessment process: click here
* For booking your assessment: click here *
Ex 000
-
Basic knowledge and awareness to enter a site that includes a classified hazardous area
-
This unit of knowledge covers the safety obligations and minimum basic knowledge of persons entering a site that has classified hazardous areas. It requires an understanding of the nature of hazardous areas, limitations on devices that may be taken into a hazardous area and the occupational health and safety responsibilities and procedures related to hazardous areas.
-
This unit is only theoretical and does not include requirements for ensuring the explosion protection aspects of plant and machinery.
Ex 001
-
Apply basic principles of protection in explosive atmospheres
-
This Unit of Competence covers the basic principles of protection in explosive atmospheres of plant and machinery. Ex 001 is based on various parts of IEC 60079 series, and it is a prerequisite for the higher units.
-
This Unit of Competence covers knowledge and skills to classify areas where explosive materials may exist.
-
Competence in this unit requires a degree, diploma or equivalent in a technical subject., see IECEx OD 504 for details.
-
This unit of competence is based on IEC 60079-10-1 and IEC 60079-10-2 and any other relevant standard that apply to this Unit of Competence.
-
The assessment is only theoretical.
Ex 002
-
Perform classification of hazardous areas
-
This Unit of Competence covers knowledge and skills to classify areas where explosive materials may exist.
-
Competence in this unit requires a degree, diploma or equivalent in a technical subject., see IECEx OD 504 for details.
-
This unit of competence is based on IEC 60079-10-1 and IEC 60079-10-2 and any other relevant standard that apply to this Unit of Competence.
-
The assessment has a theoretical part and a practical part.
Ex 003 & 006
-
Ex003 - Install explosion-protected equipment and wiring systems
-
Ex006 - Test electrical installations in or associated with explosive atmospheres
-
These two units are assessed together for installation personnel, with a focus on IEC 60079-14.
-
Both units include a review of the applicant's work- and training record. At least 3 years of relevant work experience is required, see IECEx OD 504 for details. Ex 001 is a prerequisite.
-
The assessment has a theoretical part and a practical part.
Ex 004, 007 & 008
-
Ex 004 - Maintain equipment in explosive atmospheres
-
Ex 007 - Perform visual and close inspection of electrical installations in or associated with explosive atmospheres
-
Ex 008 - Perform detailed inspection of electrical installations in or associated with explosive atmospheres
-
These three units are assessed together for inspection personnel, with a focus on IEC 60079-17.
-
All units include a review of the candidates' work- and training record. At least 3 years of relevant work experience is required, see IECEx OD 504 for further details. Ex 001 is a prerequisite.
-
The assessment has a theoretical part and a practical part.
Ex 009
-
Design electrical installations in or associated with explosive atmospheres
-
This unit includes a review of the candidates' work- and training record. At least 3 years of relevant work experience is required, see IECEx OD 504 for details. Ex 001 is a prerequisite.
-
The assessment has a theoretical part and a practical part.